SHUTTING DOWN AND CLEANING
14. After a few seconds the cleaning ball is emitted from the
spray lance.
15. Depending on the processed coating material, repeat the
cleaning process 3 – 4 times.
The mortar hose must be pressureless.
If necessary, set the selector switch briefly to "R"
(reverse).
Watch the manometer ––> 0 bar.
Wear safety goggles.
16. Set selector switch to "A".
17. Decouple mortar hose from pump unit.
A further cleaning option is to use the cleaning
i
adapter (accessory).
This cleaning adapter can be connected to
a water hose or a tap by means of the claw
coupling.
Insert cleaning ball into the mortar hose. Couple
the mortar hose to the cleaning adapter and
rinse through with water.
18
8.2
CLEANING THE DEVICE AND REPLACING THE
STATOR
1. Clean mortar spraying machine.
To do so, pump a suitable pump lubricant or water mixed
with washing-up liquid through the pump.
DISMANTLING
The mortar hose must be pressureless.
If necessary, set the selector switch briefly to "R"
(reverse).
Watch the manometer ––> 0 bar.
Wear safety goggles.
Disconnect external controls. Disassembly may
only be carried out by the person who controls
the machine.
Never operate mortar spraying machine with an
exposed rotor.
Do not reach into the rotor when it is moving.
Risk of crushing.
Caution if you have long hair. Only wear close-
fitting clothes at work.
1. Move selector switch (fig. 14, 1) to "A" and set delivery
volume controller (2) to „0".
2. Disconnect mains plug.
3. Loosen the star screws (3) and remove the outlet unit (4).
4. Set delivery volume controller (2) to 1 or 2.
5. Connect mains plug to mains power supply.
6. Move the selector switch (1) to position „F". As soon as
the stator (5) is released from the rotor (6), set the selector
switch to „A".
7. Remove the stator (5) completely.
8. Disconnect mains plug.