Clean the air inlet and outlet grilles with a vacuum cleaner
Clean the air inlet and outlet grilles with a vacuum cleaner
Clean the air inlet and outlet grilles with a vacuum cleaner.
a
WINTER
-The central heating circuit is working.
-The control box does not regulate, the
only key that works is the BOOST
only key that works is the BOOST
only key that works is the BOOST.
-The resistance does not work, it is off.
-The boiler regulates.
SUMMER
-The central heating circuit is not working..
-The control box recovers all its functions.
-The boiler does not regulate anymore.
-The resistance takes over from the boiler
that is cut.
CLEANING THE FAN
Use
USING MIXED VERSION
a
b
b
49
Supply tap to allow inlet of hot
water from the central heating.
This can be thermostatically
controlled or not depending on
your choice.
Boiler return tap to allow the hot
water to leave the central hea-
ting.
-The supply tap «a» must be open.
-The boiler return tap «b» must remain
open.
-The supply tap «a» must be closed.
-The boiler return tap «b» must remain
open.