Télécharger Imprimer la page

Extel DF-245 Guide D'installation Et D'utilisation page 27

Publicité

The roadside panel supplies a current-free "dry" contact to connect to the "push button" control of your auto-
matic gate opener.
NB: this function is only operational if communication is established with the roadside panel.
d. Connecting one or two optional extra WEPACB 247 BIS SER.R2 indoor station
1. Connect the wires as shown in the connection plan (fig.6)
2. To connect the indoor station to the extra WEPACB 247 BIS SER.R2, indoor station, 6 wires are needed for all
the functions.
1st optional indoor station:
• Terminal «3» of the response unit on terminal «3» of the extra indoor station
• Terminal «4» of the response unit on terminal «4» of the extra indoor station
2nd optional indoor station:
• Terminal «5» of the response unit on terminal «5» of the extra indoor station
• Terminal «6» of the response unit on terminal «6» of the extra indoor station
Cable calibre : • 2 x 1,5 mm
Caution : In any case, do not double the wires to increase size
6. USING
a. Using the interphone
• A call on the roadside panel will trigger an audible signal on the answering unit. You have 30 sec. to answer. Press
the key
to communicate with your visitor.
One press of the
button is enough to establish communication with the street plate.
• The keeper or electric lock is controlled using the
• The mechanism is controlled using the
• The "Monitoring" function (for listening to the street) is controlled using the
b. Indoor unit settings
3 adjustments can be accessed on the side of the indoor unit:
• Cut ringing (0). The
indicator then blinks on the front of the indoor unit.
• Melody select (1-Ding dong, 2- La lettre à Elise or 0-mute) (8).
• Melody volume control
7. TECHNICAL SPECIFICATIONS
a. Indoor unit
(PACB 245 SER.R2)
• Reference: 812245
• Power supply: 17 V
• Consumption : 17 W
• Dimensions (mm): 150x120x31
b. Power supply
• Adapter: 100-240 V~ / 50-60Hz / 17V
If the power supply cable is cut, check the polarity
c. Outdoor unit
(PAPL 245 SER.R2)
• Reference: 822245
• Operating temperature: from -10°C to +45°C.
• Protection Index: IP44
• Front dimension (mm) :115x152x37
All manuals and user guides at all-guides.com
2
wires up to 25 m
* button.
(fig.2)
(9).
/ 1500 mA
CFI EXTEL WEPA 245 SER.R2 - 09/2011
* button.
* in "communication" mode only
(fig.6)
button.
GB4

Publicité

loading

Ce manuel est également adapté pour:

Wepa 245 ser.r2Out245