WARNING
Operating or towing a machine with worn, damaged or
missing parts can result in death or serious injury. Always
replace worn, damaged or missing parts promptly. Do not
operate or tow this machine until all worn, damaged or
missing parts have been replaced, and proper operation of
the machine has been verified.
Engine
Refer to the Engine Operator's Manual for all scheduled
engine maintenance procedures (including oil, coolant, filters,
etc.).
Engine Oil Drain
The unit is equipped with a remote engine oil drain (A, Figure
21), located on the left side of the light tower trailer toward
the rear. To drain the engine oil:
1. Place an approved container beneath the oil drain.
2. Remove the oil drain plug.
3. Open the oil drain valve, located to the right of the engine
oil pan (B, Figure 21, inset).
4. Allow the engine oil to drain completely into the approved
container. Be sure to dispose of used engine oil accord-
ing to local, state, province and/or federal rules.
5. Close the oil drain valve.
6. Replace the oil drain plug, tightening securely.
7. Add oil to the engine. Refer to the Engine Operator's
Manual.
B
Figure 21
Electrical System
Generator
Refer to the Generator Operator's Manual for all scheduled
generator maintenance procedures.
22
Ballast Panels
The ballast panels are located in the engine compartment
toward the front of the light tower trailer. Service or replace-
ment of ballast and capacitors should be performed by an
authorized dealer only.
Electrocution Hazard
• Ballast and capacitors are capable of discharging high
voltage, which will result in death or serious injury.
Service or replacement should be performed by an
authorized dealer only.
Light Tower And Lamps
Changing Lamps
Burn Hazard
• The light fixtures become extremely hot during use.
• Always use caution and heat–resistant glove when
handling the lights or allow the lights to sufficiency cool
down before handling.
1. Turn off the lights and shut down the engine.
2. Allow 20 minutes for the lights to cool.
3. Lower the light tower.
4. Loosen the lens channel screws (E, Figure 22) to allow
the removal of the lens channel (F).
5. Remove the silicone gasket (G, Figure 22) and lens (H).
6. Remove the support clip screws (A, Figure 22) and sup-
port clip (B).
7. Carefully remove the old lamp (C, Figure 22), and install
the correct replacement lamp. See Specifications.
8. Clean the reflector (D, Figure 22) and lens.
9. Install the support clip and screws.
10. Install the silicone gasket and lens. Replace if worn or
damaged.
A
11. Install the lens channel and screws.
12. Test the new lamp to ensure proper operation.