Télécharger Imprimer la page

Würth ESI 200 Traduction Des Instructions De Service D'origine page 28

Publicité

Information messages
In the event of an accident, an error code is displayed in the 7-segment display.
Pressing the Electrode/TIG button causes the information message to be deleted.
Note
The machine remains functional with limitations after the information message appears; the fault
must be remedied as quickly as possible.
Fault
EEProm
H06
Read/write error
Error Messages
If a fault occurs, an error code is displayed in the 7-segment display [9]. By pressing the menu button [8]
the sub-error (sub-code) is displayed.
Note
Welding is not possible as long as an error code is displayed.
Code
Fault
E01
Overheating
E02
Power pack
E03
Current sensor
Primary current trans-
E06
former
E07
Supply voltage 15 V
Operating panel iden-
E13
tification
E14
Operating panel
28
Messages
Cause
Communication fault with EEProm
Possible cause
Admissible cyclic duration factor
exceeded
Fan defective
Power pack controller fault
Current sensor faulty
Current difference between current trans-
former and current sensor too high
Internal power supply fault
Panel identification defective
Operating panel module detective
Possible remedy
Switch machine off and on again, or carry out master
reset
Remedy
Leave the machine switched on and allow to cool
Check fan: Switch machine off and on again, fan must
come on briefly
Contact Service
Contact Service
Contact Service
Contact Service
Contact Service
Contact Service

Publicité

loading

Ce manuel est également adapté pour:

5952 000 200