3) Do not actuate the tool unless
t e tool is placed rmly against
the workpiece. If the tool is not
in contact with the workpiece, the
fastener may be de ected away from
your target.
4) Disconnect the tool from the
power source when the fastener
jams in the tool. While removing
a jammed fastener, the tacker may
be accidentally activated if it is
plugged in.
5) Use caution while removing a
jammed fastener. The mechanism
may be under compression and
the fastener may be forcefully
discharged while attempting to free a
jammed condition.
6) Do not use this tacker for
fastening electrical cables. It
is not designed for electric cable
installation and may damage
the insulation of electric cables
thereby causing electric shock or
fire hazards.
Vibration and noise reduction
To reduce the impact of noise and
vibration emission, limit the time of
operation, use low-vibration and low-
noise operating modes as well as wear
personal protective equipment.
Take the following points into account
to minimise the vibration and noise
exposure risks:
Only use the product as intended by
its design and these instructions.
Ensure that the product is in good
condition and well maintained.
Keep tight grip on the handles/
grip surface.
Maintain this product in accordance
with these instructions and keep it
well lubricated (where appropriate).
Plan your work schedule to spread
any high vibration tool use across a
longer period of time.
Behaviour in emergency
situations
Familiarise yourself with the use of this
product by means of this instruction
manual. Memorise the safety warnings
and follow them to the letter. This will
help to prevent risks and hazards.
Always be alert when using this
product, so that you can recognise
and handle risks early. Fast
intervention can prevent serious
injury and damage to property.
Switch the product o and remove
the battery pack if there are
malfunctions. Have the product
checked by a qualified professional
and repaired, if necessary, before
you operate it again.
Residual risks
Even if you are operating this product
in accordance with all the safety
requirements, potential risks of injury
and damage remain. The following
dangers can arise in connection with the
structure and design of this product:
Health defects resulting from
vibration emission if the product is
being used over long periods of time
or not adequately managed and
properly maintained.
NOTE
This product produces an
u
electromagnetic field during
operation This field may under
some circumstances interfere with
active or passive medical implants!
To reduce the risk of serious
u
or fatal injury, we recommend
persons with medical implants
to consult their doctor and the
medical implant manufacturer
before operating this product!
GB/IE
35