With dip-switch No. 5 programmed in the OFF
%
position, Motor M3 (actuator C20) is normally
controlled with the button.
Programming the dip-switch ON does not serve any
%
function.
DIP-SWITCH N.6: Operation of radio control with
w
two TF units
With dipswitch No.6 OFF the radio control operates the
%
individual opening and closure of three motors
belonging to a single TF.
With the dipswitch ON, it can operate up to 6 motors in
%
step-step mode, i.e. two separate TF units. To control
the two units, it is necessary to set the keys of the radio
control via programming of dipswitch No.2.
DIP-SWITCH N.7: Automatic" or "User present"
w
mode
With dipswitch No.7 OFF the control unit functions in
%
"AUTOMATIC" mode and the manual control, via
keyboard or remote/radio control, functions with step-
step mode (Open, Stop, Close, Stop, etc.).
With the dipswitch ON the control unit functions in
%
"USER PRESENT" mode.
DIP-SWITCH N.8: Exclusion of rain and wind
w
sensors
With dipswitch No.8 OFF the rain and wind sensors are
%
enabled on all three motors connected to the power
unit. When one of the sensors intervenes, the motors
automatically close in the following order: Motor M3
(C20 actuator) - Motor M2 (shade) - Motor M1 (blind).
With dipswitch No.8 ON, the rain and wind sensors are
%
enabled only on Motor M3 (C20 actuator).
If the power unit controls all three C20 24V actuators
@
make sure dipswitch No.8 is programmed OFF.
6.4
EMERGENCY MANEUVER
The TF unit is equipped with an emergency opening and
closure. To perform the emergency maneuver proceed
as follows:
·
Press key SP1 for about 2-3 seconds.
F
If the windows are closed there will be a general
opening in the following sequence : Motor M1 (blind)
- Motor M2 (shade) - Motor M3 (C20 actuator). If the
windows are open they will all close in the following
sequence: Motor M3 (C20 actuator) - Motor M2
(shade)- Motor M1 (blind).
&
While the motors are functioning no other operation is
possible.
6.5
RESETTING THE TF
To reset the TF and disable the radio controls
programmed, proceed as follows:
·
Press and hold key SP1;
F
the led blinks for about 5 seconds, then stays lit for
30
INSTALLATION AND USE INSTRUCTIONS
another 7 seconds, and blinks two more times
before going off completely.
·
Release the key;
·
The memory has been erased.
&
Resetting the power unit, all the radio controls
previously programs are disabled.
@
Infrared remote controls cannot be erased.
@
Perform this procedure before programming the first
radio control.
6.6
REMOTE/RADIO CONTROL TR8
The remote/radio control TR8 (fig.14) controls in manual
mode the motors connected to the power unit. It consists
of 8 keys (4 smooth and 4 knurled) and disposes of a
double system of transmission: infrared (remote control)
or radio frequency (radio control).
w
Remote control: In case of infrared transmission,
every remote control sends the receiver a signal equal
to all the others as the code used is a fixed one.
Therefore if a remote control is used in infrared mode
there is no need to program it: the control is enabled
and ready for use.
w
Radio control: In case of radio transmission, however,
every radio control sends the receiver a different signal
from all the others as the code used is variable.
Therefore the receiver must be able to recognize the
enabled radio controls.
@
Before programming the first radio control reset the
power unit as described in par. 6.5.
6.7
PROGRAMMING THE RADIO CONTROL
To program a radio control and enable it for use in radio
mode, proceed as follows:
·
place the radio control at a distance of at least 1.5
meters from the power unit and point it in the opposite
direction;
·
press and hold key SP1;
F
the led will blink for about 5 seconds and then
remains on.
·
release the key.
F
the led starts to blink again to indicate that the
power unit is waiting for a code.
F
press for about 3-4 seconds a key on the radio
control that you want to enable.
F
the led on the unit blinks at high speed and the
radio control has been programmed.
&
Repeat the above steps for every radio control you
want to enable.
&
The programming operation is concluded if the
TF33