3.3. Marking

See figure 1.
1
Adjustment screw and locknut for threshold 1
2
Adjustment screw and locknut for threshold 2
3
Option: factory setting parameters for threshold 1
4
Option: factory setting parameters for threshold 2
5
Protection index
6
Microswitch interrupting capacity and voltage
7
Device serial number
8
Identification
9
Symbol indicating «You must read the user manual»
10
QR Code leading to tracinfo, that contains CE certificate, present manual
11
Compatible wire rope diameters
12
Capacity on strand (working load limit)
All indications and labels affixed on the product by the manufacturer must be kept fully legible. If any
indications and labels are removed or damaged, they must be replaced before continuing to use the product.
Tractel
can supply new marking materials on request.
®

3.4. Technical specifications

Installation
Repeatability
Measurement sensor
Category
Cut-out voltage
Cut-out intensity
Connection
Electrical output
Lenght of cord
Calibration system
Hysteresis
Operating temperature
Protection degree
Material
Surface treatment
Maintenance
Technical Data of the Micro switches:
• Type: V4NST7-UL
• According: UL, CSA, ENEC
• Mechanical life: 5 x 10
cycles minimum (impact free actuation)
6
Maximum electrical ratings:
Recommended Maximum Electrical Ratings
Directly on idle strand
1% FS
2 integrated micro switches
Contact 1 : 1 NO, 1 NC
Contact 2 : 1 NO, 1 NC
1 (as EN ISO 13849-1)
250 VAC
2A max/inductive load
4A max/resistive load
Electrical cable, 7 conductors
Cable gland
2 meters
By screws
Between 50 and 200 kg depending on the effort
-30° to +80°C
IP67
Aerospace quality aluminium
Anodizing Body
None