Gas conversions from Natural gas to propane or from propane
to Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
14

GAS CONVERSIONS

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn the manual shut-off valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator (Natural Gas
to Propane)
1. Remove the storage drawer. See the "Remove/Replace
Drawer" section.
2. Locate gas pressure regulator at rear of the drawer
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
Propane Conversion
WARNING
Tip Over Hazard
A
A. Gas supply line
B. Manual shut-off valve closed position
C. To range
A
A. Gas pressure regulator
B
C