INSTALLATION
General
Electrical connection
EN 12
• If the cooker hood is to be fitted to an existing duct no other
appliances, such as a geyser or heater, may be connected to that
same duct.
• Bends produce resistance. Make sure that the duct has a smooth
run and has as few bends as possible. Draw the flexible pipe out
as far as possible. Before starting to drill, check that there are no
installation pipes (for gas, water, etc.) present.
• The discharge stump has a diameter of 125 mm. It is best if the
discharge pipe also has this diameter.
Attention: Make sure that there is a sufficient supply of fresh air, if an
extractor hood and a heat source (e.g. gas cooker) that both consume
air from the same room, are switched on at the same time.
The maximum permitted underpressure is 4 Pa.
The plug should be accessible after the extractor hood is fitted or it
should be possible to disconnect the extractor hood from the mains by
means of a bipolar switch with a contact gap of 3 mm.
Attention!
When making the electrical connections, take care that the voltage and
frequency correspond to the values given on the data plate.
If the connection cable becomes damaged, it should be replaced by
the manufacturer's service department or by a person with equivalent
qualifications, in order to prevent dangerous situations from arising.