3.2 End limits and motor safety chain wiring
Refer to the motor manual to locate the upper and lower limit
switches. Spot the rotation direction and connect the upper
limit switches (OPEN LS) and the lower limit switches (CLOSE
LS).
Connect the motor safety chain and the safety brake in series
on SAFETY CHAIN.
3.3 Control point wiring
If you are not using the « STOP » input, leave shunt 2 in place.
• Then connect J5 terminal (corresponding to the command buttons)
• Place the cover and screw the 4 screws.
• Power on.
(2)
M
N1
N2
(2)
K e y sw i t c h
N2
M
N1
5/6
EN