Specifications LD-64D
Transmission
Interface 1
Interface 2
Data rate
Indicators
Temperature range
Humidity
Dimension
Weight
Mounting
Power supply alternatives
Model description
Power supply
Frequency
Fuse, F1
Power consumption
Transient protection
Power/Line
Isolation, RMS
Power supply
LEDs for indication on LD-64D
• PWR:
Indicates that the unit has power.
• TD:
Indicates recevied data on RS-485 side.
• RD:
Indicates transmitting data on RS-485 side.
• Rx1:
Indicates received data on fibre channel 1.
• Rx2:
Indicates received data on fibre channel 2.
• Tx1:
Indicates sending data on fibre channel 1 from RS-485 side.
• Tx2:
Indicates sending data on fibre channel 2 from RS-485 side.
12
Asynchronous, half duplex or simplex
EIA RS-485 / ITU-T V.11
9-position D-sub alt. 5-position screw block
Fibre optical 4 ST-connections
2,4 – 375 kbit/s
PWR, TD, RD, Tx1, Rx1, Tx2, Rx2
5–50°C ambient temperature
0–95% RH without condensation
55x100x128 mm (WxHxD)
0.4 kg
On 35mm DIN-rail
LD-64D HV
95–240V AC ± 5% /
110–240V DC ± 5%
48–62 Hz / –
1 A T / 1 A T
Wickmann
30 mA
Yes/–
3 750 V
LD-64D LV
12–45V AC ± 5% /
12–55V DC ± 5%
48–62 Hz / –
1 A T / 1 A T
Wickmann
3 W
Yes/–
3 750 V
6073-2041