Electrical Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage,
■
amperage and frequency as specified on the model/serial/
rating plate. See the following illustration.
A. Model/Serial/Rating Plate
Models rated from 7.3 to 9.6 kW at 240 V (5.4 to 7.4 kW at
■
208 V) require a separate 40 A circuit.
A circuit breaker is recommended.
■
Prepare Built-In Microwave/Oven
Combination
1. Decide on the final location for the oven. Locate existing
wiring to avoid drilling into or severing wiring during
installation.
WARNING
Excessive Weight Hazard
Use two or more people to move and install oven.
Failure to do so can result in back or other injury.
2. To avoid floor damage, set the oven onto cardboard prior
to installation. Do not use handle or any portion of the front
frame for lifting.
3. Remember to remove bottom vent from the foam packing on
top of oven.
4. Remove the shipping materials and tape from the oven.
5. Remove the hardware package from inside the bag
containing literature.
6. Remove and set aside racks and other parts from inside the
oven.
7. Move oven and cardboard close to the oven's final location.
Remove Oven Door(s)
IMPORTANT: Use two hands to remove oven door.
1. Prior to removing the oven door, prepare a surface where
you will place it. This surface should be flat and covered with
a soft blanket, or use the corner posts from your packaging
material.
4
A
INSTALLATION INSTRUCTIONS
Connect directly to the fused disconnect (or circuit breaker
■
box) through flexible, armored or nonmetallic sheathed,
copper cable (with grounding wire). See "Make Electrical
Connection" section.
Flexible conduit from the oven should be connected directly
■
to the junction box.
Do not cut the conduit. The length of conduit provided is for
■
serviceability of the oven.
A UL listed or CSA approved conduit connector must be
■
provided.
If the house has aluminum wiring, follow the
■
procedure below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper connection
must conform with local codes and industry-accepted
wiring practices.
For power requirements, refer to the following table:
Model
JMW3430I
2. Open the oven door.
3. Locate the oven door hinge locks in both corners of the oven
door, and then rotate the hinge locks toward the oven door
to the unlocked position. If the door hinge lock is not rotated
fully (see illustration B), the door will not remove properly.
A. Oven door hinge lock in
locked position
4. Partially close the door to engage the door latch locks. The
door will stop at this point.
240 VAC
208 VAC
kW
kW
8.2
6.6
A
B. Oven door hinge lock in
partially unlocked position
B