2) GENERAL INFORMATION
The THALIA control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer. Fully supports EELINK protocol.
Its main features are:
-
Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
-
Electronic torque control with obstacle detection
-
Limit switch control inputs based on motor selected
-
Separate inputs for safety devices
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74. If the above-mentioned
terminals are being used, remove the relevant jumpers.
TESTING
The THALIA panel controls (checks) the start relays and safety devices (photocells)
before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.

3) TECHNICAL SPECIFICATIONS

Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Motor output current
Motor relay switching current
Maximum motor power
TERM.
DEFINITION
L
LINE
N
NEUTRAL
JP5
TRANSF
Power supply
PRIM
JP7
JP21
TRANSF SEC
10
MOT1 +
11
MOT1 -
Motor
14
MOT2 +
15
MOT2 -
20
LIGHT 24V
21
26
AUX 3 - FREE
Aux
CONTACT
(N.O.)
(Max 24V
3W)
27
41
+ REF SWE
42
SWC 1
Limit switch
43
SWO 1
for ELI 250 BT
44
SWC 2
45
SWO 2
42
SW 1
Limit switch
for PHOBOS
BT – IGEA BT
43
SW 2
50
24V-
Accessories
51
24V+
power supply
52
24 Vsafe+
22 -
THALIA
INSTALLATION MANUAL
230V~ ±10% 50Hz*
> 2MOhm 500V
-10 / +55°C
Software
mains/LV 3750V~ for 1 minute
max. 7.5A+7.5A
10A
180W + 180W (24V
)
Single-phase power supply 230V~ ±10%, 50-60Hz.
Transformer primary winding connection, 230V.
Board power supply:
24V~ Transformer secondary winding
24V= Buffer battery power supply
Connection motor 1. Time lag during closing.
Connection motor 2. Time lag during opening.
Flashing light 24V output max. 25W.
Aux 3 logic= 0 - 2nd radio channel output. Contact stays closed for 1s when 2nd radio channel is activated.
Aux 3 logic= 1 - SCA gate Open Light output.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 2 - Courtesy light command output. Contact stays on for 90 seconds after the last operation.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 3 - Zone light command output. Contact stays closed for the full duration of operation.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 4 - Stair light output. Contact stays closed for 1 second at start of operation.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 5 - gate open alarm output. Contact stays closed if the leaf stays open for double the set TCA time.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 6 - Flashing light output. Contact stays closed while leaves are operating.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 7 - Solenoid latch output. Contact stays closed for 2 seconds each time gate is opened.
In this case, the 2nd radio channel controls pedestrian opening.
Aux 3 logic= 8 - Magnetic lock output. Contact stays closed while gate is closed.
In this case, the 2nd radio channel controls pedestrian opening.
Limit switch common
Motor 1 closing limit switch SWC1 (N.C.).
Motor 1 opening limit switch SWO1 (N.C.).
Motor 2 closing limit switch SWC2 (N.C.).
Motor 2 opening limit switch SWO2 (N.C.).
Limit switch control motor 1.
For actuators with single-wire limit switch control.
Limit switch control motor 2.
For actuators with single-wire limit switch control.
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter). Output active only during operating cycle.
Accessories power supply
AUX 3
Flashing light
Dimensions
Fuses
N° of combinations:
Max. n° of transmitters that can be
memorized:
(*other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fig. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore cable
with a cross-sectional area of at least 3x1.5mm
the regulations in force.
To connect the motors, use a cable with a cross-sectional area of at least
1.5mm
of the kind provided for by the regulations in force. By way of example,
2
if the cable is run outside (unprotected), it must be at least type H07RN-F,
while if it is run inside (in a raceway), it must be at least type H05 VV-F.
DESCRIPTION
24V~ (demand max. 180mA)
24V~safe (demand max. 180mA)
NO contact (24V~/max.1A)
24V~ max. 25W
see Fig. B
see Fig. C
4 billion