Cembre B600CND Notice D'utilisation Et Entretien page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

NOTE: To display the momentary force or pressure during
the work cycle, select the appropriate display from the
menu (Ref. to section 4). When the operating button is
released before the motor stops automatically, the display
will show the peak force (Fp) or the peak pressure (Pp)
reached at that point.
To complete the cycle, press the operating button again until the motor stops automatically; the display
will show the maximum force or pressure reached followed by "OK" to confi rm correct operation.
The display "ERROR", combined with a beep and the LEDs fl ashing,
indicates an incorrect crimping procedure caused by the work cycle
being interrupted before the control parameters (force/pressure) of the
tool are reached.
This error appears when the pressure release button has been operated and the tool has already
reached a pressure >100 bar. In this case, repeat the compression by pressing and holding the op-
erating button until the motor stops automatically.
2.4) Release of dies
Once the motor has stopped automatically, release the operating button (3), the ram will return,
allowing access and release of the dies.
The oil discharge to reservoir can also be performed in manual mode (Refer to § 4.2 for
further details).
2.5) LED Worklights
Whilst the tool is in operation, the compression area is illuminated by four high luminosity LED
Worklights that switch off automatically at the end of the cycle.
The LED Worklights can be disabled by following the procedure described in section 4.3.
2.6) Head rotation
For ease of operation, the tool head can rotate through 180°, allowing the operator to work in the
most comfortable position.
Do not attempt to rotate the head when the hydraulic circuit is pressurised.
2.7) Capacitive touch button for menu selection
This button is located under the display and allows selection of various
screens (Ref. to section 4); accessible only when the display is on.
Wearing gloves or using other objects may inhibit the operation of the
button, therefore use a bare fi nger to apply only a light touch.
Fm = 67.4 kN
F
= 67.4 kN
m
F
= 67.3 kN
p
P
= 742 bar
m
P
= 741 bar
p
OK
P
= 742 bar
n
OK
ERROR
BEEP