To convert to Natural gas, the Natural Gas Conversion Kit Part
Number W10118098 must be used. Follow instructions included
with the kit.
C
D
A. Grill gas pipe
B. New ANSI Z21.54 certified gray hose
C. Rear of grill
D. To Natural gas supply
Gas Connection Requirements
Style 2 - Built-In Outdoor Grills
Natural Gas
Built-in grill models are equipped for use with Natural gas. They
are design-certified by CSA International for LP (propane or
butane) gases with appropriate conversion.
Built-in models are set for Natural gas use and have a pressure
regulator with ½" female pipe threads.
A
A. Grill gas pipe
B. New CSA International approved
"outdoor" flexible gas supply line
C. Rear of grill
D. To Natural gas supply
12
A
B
B
C
D
The supply line shall be equipped with an approved shutoff valve.
This valve should be located in the same area as the grill and
should be in a location that allows ease of opening and closing.
Do not block access to the shutoff valve. The valve is for turning
on or shutting off gas to the grill.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To grill
LP Gas Conversion Using a Local LP Gas Supply
Conversion must be made by a qualified person. A qualified
Natural gas technician shall provide the LP gas supply to the
selected grill location in accordance with the National Fuel Gas
Code ANSI Z223.1/NFPA 54 - latest edition, and local codes.
To convert to LP gas, the LP Gas Conversion Kit Part Number
W10118099 must be used. Follow instructions included with kit.
A
A. Grill gas pipe
B. New CSA International approved
"outdoor" flexible gas supply line
C. Rear of grill
D. To local gas supply
LP Gas Conversion Using a 20 lb LP Gas Fuel Tank
To convert to LP gas, the LP Gas Conversion Kit Part Number
W10118099 must be used. Follow instructions included with kit.
A 20 lb LP gas fuel tank must be purchased separately.
B
C
B
C
D