WIRING (IPB9IQT)
Note: This range hood must be properly
grounded. The unit should be installed by a
qualified electrician in accordance with all
applicable national and local electrical
codes.
1. Remove the wiring box cover. Remove a
knockout from the wiring box (Fig.13).
2. Secure the conduit to the wiring box
through a conduit connector.
3. Make electrical connections. Connect white
to white, black to black and green to green.
4. Replace wiring box cover and screws. Make
sure that wires are not pinched between
cover and box.
ADDITIONAL EXTERNAL
BLOWER WIRING (IPB9E)
1. Run 2-wire plus ground power cable from
the exterior blower to the hood's wiring
box marked "motor connection" (Fig.14).
2. Remove the cover from the wiring box and
remove one knockout.
3. Feed 6" of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector.
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground.
5. Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
Exterior blower connection:
1. Make electrical connections at the exterior
blower (see instructions provided with the
exterior blower).
CONNECT DECORATIVE FLUE
1. Attached the two lower flue parts to the
support frame by overlapping the lateral
magnets (Fig.15).
WIRING BOX
COVER
BLOWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
BOX MARKED
"MOTOR
CONNECTION"
- 13 -