Télécharger Imprimer la page

Energizer eZV3500P Guide De L'utilisateur page 68

Publicité

2.3 CONTROL FUNCTIONS
AC Circuit Breakers
  While the generator is running, the breakers should be put in the ON
position.
  If the current has exceeded its limits it will automatically pop out to the
OFF position. Reduce the electrical load on the generator and push the
button back to the ON position.
AC Parallel Socket (If Equipped)
  This socket allows two approved eZV inverter generators to be
connected for additional power. The parallel kit is an optional
accessory, please contact your dealer or visit us online to purchase.
DC Circuit Breakers
  The DC circuit breaker automatically shuts off when the charging circuit
is overloaded.
  If the current has exceeded its limits the breaker will automatically pop
out to the OFF position. Reduce the electrical load on the generator and
push the button back to the ON position.
Display Button
  Press the DISPLAY button once to turn on the backlight. The hourmeter
will be shown, and the backlight will turn off after 10 seconds. Press the
DISPLAY button multiple times to cycle through different information
displays. The display is only powered while the unit is running.
EcoMode (Economy Control Switch)
  Turning EcoMode to ON is recommended for minimizing fuel
consumption. In this mode the engine will dynamically meet the demand
of the current electrical load and will automatically go into an idle state if
all electrical loads are disconnected.
  Before connecting or removing a high load device to the generator, turn
EcoMode to OFF until that device has reached running power.
  When EcoMode is OFF, the engine runs at full speed.
7

Publicité

loading