Request alarm condition time-outs
Command:
OSS?
Example:
OSS?
Get a list of the alarm condition time-outs on both inputs.
Alarm SMS content when input 1 tension is high
Command:
TIN1A:xxxxxxxx
Example:
TIN1A: TENSION ON INPUT 1
When tension is detected on input 1, an SMS is sent out with text "TENSION ON INPUT
1".
Default: ALARM! INPUT 1 HIGH
Note: a semi colon (;) is not allowed inside the message
Alarm SMS content when input 1 tension is low
Command:
TIN1B:xxxxxxxx
Example:
TIN1B1: NO TENSION ON INPUT 1
When no tension is detected on input 1, an SMS is sent out with text "NO TENSION ON
INPUT 1".
Default: ALARM! INPUT 1 LOW
Note: a semi colon (;) is not allowed inside the message
Alarm SMS content when input 2 tension is high
Command:
TIN2A:xxxxxxxx
Example:
TIN2A: TENSION ON INPUT 2
When tension is detected on input 1, an SMS is sent out with text "TENSION ON INPUT
2".
Default: ALARM! INPUT 2 HIGH
Note: a semi colon (;) is not allowed inside the message
Alarm SMS content when input 2 tension is low
Command:
TIN2B:xxxxxxxx
Example:
TIN2B: NO TENSION ON INPUT 2
When no tension is detected on input 1, an SMS is sent out with text "NO TENSION ON
INPUT 2".
Default: ALARM! INPUT 2 LOW
Note: a semi colon (;) is not allowed inside the message
Activate a relay output
Command:
OUTx:ON
Example:
OUT1:ON
Activate output relay 1
Deactivate a relay output
Command:
OUTx:OFF
Example:
OUT2:OFF
Deactivate output relay 2
15/12/2011
xxxxxxxx = message (max. 100 characters, all capitals)
xxxxxxxx = message (max. 100 characters, all capitals)
xxxxxxxx = message (max. 100 characters, all capitals)
xxxxxxxx = message (max. 100 characters, all capitals)
x = 1 (output 1) or 2 (output 2)
x = 1 (output 1) or 2 (output 2)
HAMGSM133