ELECTRICAL
INSTALLATION
ATTENTION!
QUALIFIED INSTALLER OR
SAT
PANDO ONLY
CAUTION!
THE ELECTRICAL INSTALLATION
OF THE OVEN MUST BE CARRIED OUT BY
A QUALIFIED INSTALLER OR A SPECIALIST
FROM THE PANDO TECHNICAL SUPPORT
SERVICE.
IF ANY DAMAGE OCCURS DURING THIS
PROCESS THAT HAS BEEN CARRIED OUT BY
AN UNQUALIFIED USER OR PERSONNEL, IT
WILL NOT BE COVERED BY THE WARRANTY,
EVEN IF IT IS STILL VALID!
Please note.....
•
To connect the oven to the mains, the installer
must use a power supply cable type H05RR-F,
H05SS-F or H07RN-F.
•
The connection must be made through an om-
nipolar circuit breaker, suitable for the current
to be withstood and with a minimum opening
between contacts of 3 mm for disconnection
in cases of emergency, cleaning or lamp re-
placement. Under no circumstances may the
earthing cable pass through this switch.
•
Any manipulation or repair of the appliance,
including replacement of the power cable,
must be carried out by authorised service
personnel using original spare parts. Repairs
or handling carried out by other persons may
cause damage to the appliance or malfunc-
tion, endangering its safety.
•
This switch can be replaced by a plug, provi-
ded that it is accessible in normal use.
•
The oven must always be connected to a
good earth connection in accordance with
current regulations.
•
Switch off your oven when it is out of order.
Interpretation of power supply wires:
1. Brown or Black = Line/Phase (L)
2. Blue = Neutral (N)
3. Green/Yellow = Grounding
2 2 0 - 2 4 0 V
1
2
3
ENERGY EFFICIENCY
EN 60350-1
Please note the following information:
1. The measurement is carried out in the
"ECO" function to determine the label class
data.
2. The measurement is carried out in the
"Upper and lower heating" to determine the
data for the conventional mode.
English
1N
L
N