4.1.c - Installing and connecting the
batteries (Fig. 6)
WARNING:
CHECK THAT THE RECOVERY TANK AND
THE CLEAN WATER TANK ARE EMPTY.
-
Disconnect the plug (35).
-
Press the button (36) and lift the tank (14)
until completely overturned.
-
Position the batteries (37) as shown in
the figure and connect them as shown on
the chart in Fig. 6 using the cables sup-
plied.
-
Tighten the terminals (38) using an insu-
lated wrench.
-
Lower the tank (14) until a coupling "click"
is heard.
-
Connect the plug (35) to the upper socket
(39).
N.B.:
The battery must be connected by special-
ised personnel.
5.1 CHARGING THE
BATTERY
DANGER:
Charge the batteries in rooms which are
well-ventilated and comply with applica-
ble regulations in the country of use.
For safety-related information, follow
what is described in chapter 1 of this
manual.
WARNING:
For information and warnings about the
battery and on board battery charger (if
present) follow what is described in the
battery charger manual enclosed with
this document.
WARNING:
When the machine leaves the factory, it is
calibrated to operate with gel batteries.
If other types of batteries are installed,
see the paragraph "Parameter setting".
The use of gel batteries with calibration
for acid or other batteries is prohibited.
NOTE:
10 hours are needed for complete battery
charging. Avoid partial recharges.
5.1.a - Charging the battery using the
on board battery charger (if
present) (Fig. 7)
-
Move the machine close to a mains elec-
tricity socket.
-
Remove the battery plug (35) from the
system socket (39).
-
Connect the battery plug (35) to the on
board battery charger (16) socket (40).
WARNING:
It is important to first connect the plug (35)
to the socket (40) of the battery charger
and then connect the battery charger to
the mains socket, otherwise the batteries
will not charge.
-
Take the cable (41) from its seat and con-
nect it to the socket (42) on the machine,
then connect the other end to the mains
power socket.
-
Check that the green LED (43) flashes
2 times and then goes from the color
"Green" to continuously lit "Red".
WARNING:
Make sure that the mains electrical volt-
age is compatible with the battery charg-
er's operating voltage (230 Vac for the Eu-
ropean market; 115 Vac for the American
market; 50/60 Hz).
-
Leave the batteries to charge until the
"Green" LED (43) lights up, then remove
the power cable (41) and put it away.
-
Reconnect the battery plug (35) to the
system socket (39).
EN-6