Fault Description
MOSFET OTP fault
Fan stop
Discharge soft start fault
Charge soft start fault
MOSFET UTP fault
PV hardware OCP fault
PV1 software OCP fault
Car charge output OCP fault
PV output OVP
(over voltage protection) fault
PV1 input OVP
(over voltage protection) fault
PV1 OTP fault
Abnormal communication
Battery voltage is too low,
The battery is broken
AC cable
Car charging cable
After removing the device and restarting, the fault is cleared.
Exclude the fan abnormality, turn on and off,
contact after sales if still not fixed.
Auto recover after fault is cleared.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Automatic recovery after the product heats up.
Remove PV charge, auto recover after connecting PV and turn on.
Stop PV1 charging, auto recover after connecting PV and turn on.
Turn off output, manual recover after fault is cleared.
Removing the PV charging interface will automatically
restore it after a certain period of time.
Remove the PV charging interface for a certain period of
time to automatically recover or check whether the PV output
Stop PV1. Auto recover after fault is cleared.
Turn on and off, or change operation environment.
Contact after sales if still not fixed.