ENERGIZER SOLAR PEAK 300
Error Messages & Solutions
Icon
Icon Characteristics
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Fault Description
Pressure difference is too large
Battery OTP
(over temperature protection) fault
Battery UTP
(under temperature protection) fault
OCP (over current protection) fault
Abnormal precharge
Battery under voltage fault
Abnormal INV battery voltage
Grid voltage or frequency fault
Abnormal INV BUS voltage
Abnormal INV output
INV discharge overload
Charge overload
INV Tz
INV output short
13
Solution
Automatic recovery after fault clearing; 3 consecutive locks within a
certain period of time, longer recovery time.
Shut down, after temperature recovery, rechargeable activation.
Shut down, after temperature recovery, rechargeable activation.
Remove the over-power device, and it will automatically recover
after the fault is cleared; if it is triggered continuously for 3 times
within 1 minute, it will be locked, and the recovery time will be
prolonged, and it can be recovered by powering on and off again.
Power on and off again to clear the fault.
Repeated charging failures or failure to charge,
please contact customer service.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
The fault is cleared when the grid returns to normal.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Remove the over-power device, and it will automatically recover
after the fault is cleared; if it is triggered continuously for 3 times
within 1 minute, it will be locked, and the recovery time will be
prolonged, and it can be recovered by powering on and off again.
Automatic recovery after the fault is cleared; if it is triggered 3 times
within 1 minute, it will be locked, and the recovery time will be
extended, and it can be recovered by powering on and off again.
Auto recover after fault is cleared.
Fault will be cleared after reboot.
ENGLISH