People working in wastewater systems must be vaccinated
against the pathogens that may be found there. For the sake of
your health, be sure to pay meticulous attention to cleanliness
wherever you are working.
Make sure that there are no toxic gases in the working area.
Observe the health and safety at work regulations and make
sure that a first-aid kit is to hand.
In some cases, the pump and the pumping medium may be hot
and could cause burns.
For installations in areas subject to explosion hazards, special
regulations apply!
SAFETY INSTRUCTIONS COMPLI S1
NOTICE! During prolonged operation, odours may develop due
to the heat generated.
Warning!
Surface of the pump can be hot!
Minor or severe injuries due to heat!
Wear gloves and touch the pump cautiously.
NOTICE! The Compli S1 must be installed in a separate loca-
tion or a protective device must be installed.
Access by unauthorised persons is prohibited!
AREAS OF APPLICATION
The Compli sewage lifting stations are TÜV certified and are
suitable for the disposal of wastewater from toilets and urinals,
and domestic wastewater containing the usual impurities.
The units have a level controller that switches the pump on and
off depending on the level of the water. An integrated alarm
system beeps if there is a malfunction, even if this is only tem-
porary.
If the pump overheats, the motor cuts out due to the winding
thermostat. After the thermostat has switched off the system,
pull out the mains plug before remedying the fault, since the
device can switch itself on again automatically if the power is
still connected.
The tanks can withstand submersion to a depth of not more
than 1 m of water and a submersion period of up to 7 days.
The control unit cannot withstand submersion, but is splash-
proof in accordance with IP 44.
If installed in compliance with the regulations and used prop-
erly, then this control unit meets the protective requirements
of the EMC Directive and is suitable for domestic use and con-
nection to a power supply from the grid. When connected to
an industrial mains within an industrial operation with power
supply provided by a company-own high-voltage transformer,
insufficient immunity to interference has to be expected.
When using the pumps, the relevant national laws, regulations
and stipulations must be adhered to, for example:
• Sewage disposal units for building and ground drainage
systems (e.g. EN 12050 and 12056 in Europe)
• Installation of low voltage systems (e.g. VDE 0100 in Ger-
many)
• Safety and working materials (e.g., BetrSichV and BGR 500
in Germany)
• Safety in wastewater systems (e.g., GUV-V C5, GUV-R 104
and GUV-R 126 in Germany)
• Electrical systems and operating resources (e.g., GUV-V A3
in Germany)
• Explosion protection EN 60079-0,
EN 60079-1, EN 60079-14, EN 60079-17 and EN 1127-1
Scope of supply
• Tank with pumps and clamp flange for inlet
• Reducer DN 150 / DN 100 for Compli 1000
• Slip-on socket pipe for ventilation pipe
• Connection flange for pressure pipe
• Flexible connection with hose clamps for the pressure pipe
• Plug-in seal(s) for the diaphragm hand pump or additional DN
50 inlet
• Fixing materials for tank
• Non-return valve for the pressure pipe
• Control
Mode of operation: Continuous operation S1; see "Technical
Data"
ENGLISH