INSTALLATION
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the
floor is of combustible material.
US: The floor pad or non-combustible surface should be
large enough to cover at least the area under the product
and 6" (152 mm) beyond the front and beyond each
side of the fuel loading and ash removal openings. Floor
protection must extend under and 2" (51 mm) to each
side of the chimney tee for an interior vertical installation.
Canada: Require a minimum of 450 mm [17.7"] beyond
the front of the unit and 200 mm [7.8"] beyond each side
of the unit. A Floor Protector of 1/4" thick is recommended
for this installation.
A
C
FLOOR PROTECTOR
A
Rear
B
Front
C
Side
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
C
B
1"
25 mm
6"
152 mm
6"
152 mm
5
D
Backwall to unit
E
Sidewall to flue
Sidewall to top edge of
F
unit
G
Backwall to Flue
H
Adjacent wall to unit
J
Alcove depth
K
Alcove height
BACK WALL
E
D
F
H
H
K
8"
203 mm
12-1/2"
317 mm
8"
203 mm
2"
50 mm
3"
76 mm
36"
914 mm
60"
1524 mm
BACK WALL
G
E
F
H
H
J