installation, apply a standard double pole switch that ensures complete disconnection from the mains in category III
overvoltage conditions, in accordance with the installation rules. • Warning! The power cable must be replaced by the
authorised technical support service or by a person with similar qualifications.
● Please note! Before reconnecting the circuit to the mains power supply, make sure that it is working correctly, always
check that the power cable is correctly installed.
Please note! Do not use with a programmer, timer, separate remote control or any other device that activates
automatically.
RECOMMENDATIONS FOR USE
Recommendations for correct use in order to reduce the impact on the environment: When cooking begins, the device
should be turned on at minimum speed, and left on for a few minutes even after cooking is complete. Increase the speed
only if there is a large quantity of fumes and steam, using the Booster function only in extreme cases. To keep the odour
reduction system running efficiently, replace the carbon filter/s when necessary. To ensure the high performance of the
grease filter, clean it when necessary. To improve efficiency and minimise noise, use the maximum duct diameter
indicated in this manual.
USE
The extraction system can be used in the duct-out version with external evacuation, or in the recirculating version with
filtering and internal recirculation.
Duct-Out Version:
Vapours are evacuated outside through an exhaust pipe attached to the connecting flange.
CAUTION! If the product features one or more carbon filters, they must be removed.
Connect the product to wall-mounted exhaust pipes and holes with a diameter equivalent to the air outlet (connecting
flange).
The use of pipes and outlet holes in the wall with a smaller diameter will reduce the extraction performance and drastically
increase the noise level.
All responsibility in this regard is therefore denied.
• Use a ducting pipe with the shortest length necessary.
• Use a ducting pipe with the least number of bends possible (maximum bend angle: 90°).
• Avoid drastic changes in the ducting pipe diameter.
Recirculating Version:
The suctioned air will be degreased and deodorised before it is sent back into the room. To use the product in this version,
it is necessary to install an additional activated carbon filter system.
ASSEMBLY BEFORE INSTALLATION
• Check that the product is the right size for the installation area.
• Remove the activated carbon filter(s) if supplied (see also relevant paragraph).
• It(they) must be reinstalled if the product is used in the filter version.
• If there are panels and/or walls and/or wall units on the sides, make sure that there is enough space to install the product
and that it is always possible to access the control panel easily.
• The product is equipped with fixing plugs suitable for most walls/ceilings. However, it is necessary to consult a qualified
technician to make sure that the materials are suitable for the type of wall/ceiling. The wall/ceiling must be strong enough
to support the weight of the hood.
LED temperature adjustment
Once the product has been installed, before refitting the grease filter and the perimeter suction panel, it is possible to
adjust the temperature of the LED, from warm light to cool light, in order to match it with the light in your room.
The available temperatures are:
W = 3000K warm
N = 3500K medium warm
C = 4000K cool.
8