Tab. 6:
Technical data
EN
66
Technical data
Property
Backset: Tubular frame door and timber door
Distance for Swiss round cylinders
Distance for Euro profile cylinders
Follower
Rebate gap
Deadbolt throw
Maximum door weight (exceptions are only permitted
with the written consent of ASSA ABLOY (Schweiz) AG.)
Maximum pre-load
Material:
Faceplate, follower, lock latch and bolt
Strength
Burglar resistance
Bolt counterforce
Static lock latch load
Static bolt load
Installation position
Weight (without packaging)
Maximum unlocking time
· In escape direction (mechanical unlocking)
· With motorised unlocking
· In Day mode
Approval for fire doors
Test certificate number:
Operating temperature
Version
30 mm to 80 mm (in 5-mm steps)
94 mm
92 mm
9 mm
3 mm to 6 mm
20 mm
200 kg
5000 N
Stainless steel
DIN 18251 - Class 5
6000 N
5000 N
10,000 N
Vertical
1.1 kg
1 s
1.5 s
1 s
P-14-002045-PR01-ift
-20°C – +60°C