No. Description
1
Door drive unit/release: Make
2
Fault: Control unit: Open contact
3
Door contact: Contact setting depending on lock (trip latch) and input
X13
4
Cylinder contact: Contact switches when cylinder is actuated
5
Bolt contact: Contact switches immediately with sFlipLock bolt
6
Door handle contact: Door handle contact left switches immediately
7
External handle coupled: Door handle contact opposite to escape
direction switches when coupled and with e-access handle status
displayed on the right
8
Outputs
9
LED status inputs
10
Inputs
11
Factory settings: Terminals 16 and 15 bridged
12
External door contact (Reed): Monitoring contact (open)
manufacturer´s recommendation (bolt protection function)
13
External timer day/night/Office function: sFlipLock/FlipLock perma-
nent release without activation TA(X1), flip latch released.
14
Locked: All inputs are inactive. sFlipLock locked.
15
Motorised unlocking: Unlocked/flip latch released. Input only active
when Day mode or DAY TA(X1) has 1.5-s impulse
16
External timer day/night/Day mode: Couple door handle in opposite
direction to escape direction.
17
Impulse button: Bolt will be retracted by 70%, flip latch blocked.
18
Access control (reader): Impulse present = coupling in time. Door
handle coupled in opposite direction to escape direction
19
Impulse button/Unlock impulse: Unlocked, flip latch released. Impulse
and permanent release. TA(X1) controlled as long as Impulse input is active.
20
Access control (reader): If DIP 5 ON and DIP 6
OFF, then TA(X1) 1.5 s
21
External timer for day/night/Impulse and timer: e.g. by introducing a
TA(X1) 1.5-s impulse DIP 5 ON /6 OFF
22
Key switch: e.g. door drive unit Fresh Air/Office function DIP 5/6 OFF
23
DIP 2 OFF = operating current (closed when deenergised)
DIP 2 ON = closed-circuit current (open when deenergised)
24
Reserve
25
6-pin connection cable LIYY 2x2x0.22 + 2x0.5 MSL item 10/20 m
14471403/04
26
DIP switch functions (separate operating instructions AWS, page 8)
27
Service button: Function (separate operating instructions for AWS,
page 14)
Assembly
No. Description
28
Jumper JP3: Factory setting item 1
Item 2. 120 Ω on RS485 X16 with terminating resistor if data bus faults
occur
29
Jumper setting JP4: Factory setting item 1
Item 2. 120 Ω on RS485 X16 with terminating resistor if data bus faults
occur
30
Finger scanner: (RS 485 BUS)
31
MOD BUS: WAGO node (RS 485 BUS)
32
Output supply: as well as X15 without S1
33
Fuse and LED: Function (separate operating instructions for AWS, pages
8 and 12)
34
Supply: 11–27 V DC +/- 10%
35
BMZ: Fire alarm input. Fire control system
LED status outputs
36
Evaluation control system (AWS) V1.1
37
Door drive unit = TA
38
LED status outputs
39
Fault
40
Door
41
Jumper setting item 1: 1 jumper in the middle. 24 DC/AC must be
present on terminals 38 and 39 for operation. (Triggered on loss of
voltage)
Jumper setting item 2: 2 jumpers one above the other. Terminals 38
and 39 must be bridged for operation. If the BMZ is triggered, then
these bridges must be separated by the BMZ (factory setting)
42
Cylinder
43
Bolt
44
Door handle in escape direction (e-access door handle left)
45
Door handle opposite to escape direction (e-access door handle right)
46
Door contact
47
Office function
48
Locked
49
Radar
Pulse/continuous signal (handle coupling)
50
Pulse motorised 100% opening
51
52
GND
53
LED mode: Flashes when faults occur
54
Connection for sFlipLock
EN
65