No. Description
1
Door drive unit/release: Make
2
Fault: Control unit: Open contact
3
Door contact: Contact setting depending on lock (trip latch) and input
X13
4
Cylinder contact: Contact switches when cylinder is actuated
5
Bolt contact: Contact switches immediately with sFlipLock bolt
6
Door handle contact: Door handle contact in escape direction
switches immediately
7
Free/delayed bolt contact: Free: Bolt contact switches immediately.
Delayed bolt contact: Bolt contact switches with 1.5-s delay.
8
Outputs
9
LED status inputs
10
Inputs
11
Factory settings: Terminals 16 and 15 bridged
12
External door contact (Reed): Monitoring contact (open)
manufacturer´s recommendation
13
External timer day/night/Office function: sFlipLock permanent door
release without activation TA(X1), flip latch released.
14
Locked: All inputs are inactive. sFlipLock locked.
15
External radar: Input only active if Office function or Day mode TA has
1.5-s impulse
16
External timer day/night/Day mode: Bolt will be retracted by 70%. Flip
latch fixed.
17
Impulse button: Impulse and permanent release. TA(X1) controlled as
long as Impulse input is active.
18
Access control (reader): If DIP 5 ON and DIP 6 OFF, then TA(X1) 1.5 s.
19
External timer for day/night/Impulse and timer: e.g. by introducing a
TA(X1) 1.5-s impulse DIP 5 ON /6 OFF
20
Key switch: e.g. door drive unit Fresh Air/Office function DIP 5/6 OFF
21
Internal radar
22
sFlipLock
23
Reserve
24
6-pin connection cable LIYY 2x2x0.22 + 2x0.5 MSL item 10/20 m
14471403/04
25
DIP switch functions (separate operating instructions AWS, page 8)
26
Service button: Function (separate operating instructions for AWS,
page 14)
27
Jumper JP3: Factory setting item 1
Item 2. 120 Ω on RS485 X16 with terminating resistor if data bus faults
occur
Assembly
No. Description
28
Jumper setting JP4: Factory setting item 1
Item 2. 120 Ω on RS485 X18 with terminating resistor if data bus faults
occur
29
Finger scanner: (RS 485 BUS)
30
MOD BUS: WAGO node (RS 485 BUS)
31
Output supply: as well as X15 without S1
32
Fuse and LED: Function (separate operating instructions for AWS,
pages 8 and 12)
33
Supply: 11–27 V DC +/- 10%
34
BMZ: Fire alarm input. Fire control system
35
Evaluation control system (AWS) V1.1
36
Door drive unit = TA
37
LED status outputs
38
Fault
39
Door
40
Jumper setting item 1: 1 jumper in the middle. 24 DC/AC must be
present on terminals 38 and 39 for operation. (Triggered on loss of
voltage)
Jumper setting item 2: 2 jumpers one above the other. Terminals 38
and 39 must be bridged for operation. If the BMZ is triggered, then
these bridges must be separated by the BMZ (factory setting)
41
Cylinder
42
Bolt
43
Door handle in escape direction
44
Free/delayed bolt contact
45
Door contact
46
Office function
47
Locked
48
Radar
49
Day mode
50
Impulse
51
GND
52
LED mode: Flashes when faults occur
53
Connection for sFlipLock
EN
63