Fig. 5 :
1
Trip latch
2
Flip latch
3
Bolt
Motorised unlocking
Panic function
Functions and operation
Functions and operation
Self-locking function
1
2
3
Unlocking function
Unlocking from the outside and inside
The sFlipLock access is opened from the outside using the cylinder switch function or by an electrical
impulse that allows the door to be opened in less than 1.5 s.
The sFlipLock e-access is opened from the outside using the cylinder switch function or by an electrical
impulse that only retracts the bolts back to 5 mm. The flip latches remain blocked. At the same time, the
outside lever handle is coupled to the motor (in the opposite direction to the escape direction) and the
door is completely unlocked by actuating a door handle. The outside lever handle can be coupled to the
motor in less than 1.5 seconds.
Unlocking from the inside
The lock can be unlocked from the inside at any time using the panic function, even if the motor is
switched off or not working.
The lock is mechanically self locking and the door is, therefore,
always locked when in a closed state. The lock is unlocked by the
motor drive unit or by mechanical actuation.
Functional locking principle
When the door is closed, the extended flip latches (Fig. 5 –
pressed inwards onto the strike plate. If the flip latches are
pressed in, the trip latch can also be (–
door is completely closed, the flip latches slide into the latch
opening in the strike plate and are then extended again. The trip
latch remains pressed in.
When the flip latches are extended and the trip latch is pressed in
at the same time, then the bolts (–
by a spring mechanism.
The locking process is concluded.
If the lock is connected to the evaluation control system, a status
message displays the door status and locking status via the
respective evaluation contact.
2
) are
1
) pressed in. When the
3
) are released and extended