Télécharger Imprimer la page

Numatic TBL4045/50 Traduction Du Manuel D'utilisation D'origine page 83

Publicité

GB
READ MANUAL BEFORE USE
Precautions when working with batteries
1.
Always wear protective clothing e.g. face visor, gloves and overalls when working with batteries.
2.
Whenever possible always use a properly designated and well-ventilated area for charging.
Do not smoke or bring naked fl ames into the charging area.
3.
Remove any metallic items from hands, wrists and neck i.e. rings, chains etc. before working on a battery.
4.
Never rest tools or metallic objects on top of the battery.
5.
When charging is complete disconnect from the mains supply.
6.
The batteries must be removed from the machine before it is scrapped.
7.
The machine must be disconnected from the supply when removing the battery.
8.
To remove the batteries:- Disconnect machine from the mains supply (if charging) and ensure batteries are switched
off using the button that is placed on the battery top. Disconnect hoses from separator and tanks.
Remove separator and tanks. Unscrew battery strap fi xings and remove.
Undo battery terminals and remove. Remove batteries.
9.
The batteries are to be disposed of safely, as according to local government guidelines.
10. Only use genuine Numatic replacement batteries.
11. Do not allow the batteries to become fully discharged; it may not be possible to re-charge them.
Batteries should not be discharged below 22.5 volts with 10 amps fl owing.
12. Do not allow one battery to be discharged separately to the other.
13. Do not mix batteries from diff erent machines.
14. The batteries fi tted to this product are Lithium-ion (Li-ion), Lithium Iron phosphate (LFP) type.
The fi tting of any other type of battery may cause a safety hazard.
15. Switch off the battery using top ON/OFF button before cleaning or maintenance.
Battery Care
1.
Battery Storage:
a.
Batteries must be stored in a dry, level and clean location not exceeding a temperature range of 15°C ~ 25°C.
b.
Batteries must by fully charged every 6 months when on-the-shelf or if the battery voltage reduces to 25V.
c.
Batteries must be put into use within 12 months of the date of manufacture, failure to do so will lead to reduced capacity in
the fi eld. (battery date code) -
d.
If a battery does not want to switch ON and the green LED on the top is not illuminating, irreversible damage has
occurred. Under this condition, a battery should not enter into service and should be disposed of according to local
authority guidelines.
2.
During Use:
a.
Batteries must be recharged after every use regardless of machine run time.
b.
If the machine is to be left dormant for any length of time complete the following:
i.
Fully charge the batteries.
ii.
Do not leave batteries dormant for more than 6 months.
Daily
Keep the machine clean.
Ensure brushes/ pads/ squeegee/ fi lters are in good condition.
Check for any worn or damaged parts and replace immediately.
Drain and rinse dirty water tank after every use.
Store machine with brush deck secured in the elevated position.
Weekly – as daily and –
Check brush or pad and skirt and rinse.
Check fl oor tool blades for wear and wipe clean.
Clean separator assembly including fi lter and check condition of seal.
Flush out system with clean water and clean fi lters.
Batteries
Always re-charge the batteries after use.
Charge for a minimum of 4 hours. Leave the battery on charge overnight, at least once per month.
After it has been fully charged, this will prolong battery life.
Information for Scrubber Dryer
ZP19006F YYW W0 0001
Serial number
Week of Production
Year of Production