Changing the Floor Tool Blades
GB
!
Floor Tool Overview
1. Retaining pins x 4
2. Front blade (slotted)
3. Blade carrier
4. Rear blade
5. Floor tool main body
Note: The blades are designed to be
reversible, thus extending their useful
working life.
Always ensure that the machine is switched off prior to maintenance.
1
2
3
4
5
To clean the floor tool, remove securing-pin and pull-free from
the holder.
Rinse the floor tool assembly with clean water and refit.
Periodically the floor tool blades should be examined and
checked for wear and damage.
The blade removal is easy. Simply start by removing the four
retaining pins, turn the floor tool over and separate the blade
carrier from the body.
Peel away the blades from their locating lugs and examine or
renew as required.
Replacement is a reversal of the removal process.