INSTALLATION
General
GB 12
This appliance should be connected to the mains power by a registered
installer, who knows and applies the correct safety specifications.
We hereby declare that our products satisfy the applicable European
directives, orders and regulations, as well as the requirements stated in
the referenced standards.
Important information:
• The distance between the lowest point of the cooker hood and
a gas hob should be at least 65 cm. With an electric, ceramic or
induction hob this distance should be at least 55 cm.
• Follow the applicable local regulations regarding the ventilation of
gas appliances.
• The cooker hood will work better with a short outlet pipe and the
fewest bends possible.
• Prior to drilling check that there are no pipes or cables present.
• The cooker hood connection pipe is 120 mm, 125 mm or 150 mm
in diameter. Use the largest possible (150 mm) flue of the same
diameter.
• The installation material provided with this cooker hood is suitable
for reinforced concrete and brick walls. You will need special plugs
and screws for certain walls.