28
Testing in/out,
water and cleaning
Testing the flow sensor
option
(only if present)
© 04/07 Mettler-Toledo AG, CH-8606 Greifensee
Printed in Switzerland
NOTICE
All processes can be interrupted by means of "Reset" (simultaneously pressing the "In/Out"
and "Water" keys). After reset the EasyClean performs a rinse cycle. Finally, the housing
always moves into the service position. If you want to move the housing back to the mea-
suring position press the "In/Out" key.
EasyClean 350 e displays only its own errors, malfunction of the transmitter is indicated on
the transmitter. Error messages remain until they are cleared with "Reset" or the unit returns to
normal operation status.
NOTICE
During the function test, check that all hose connections are sealed and securely attached.
You can check that the housing is working by pressing the "In/Out" key.
Check the rinsing and cleaning processes in the program sequence by pressing the relevant
button ("Water" or "Clean").
1. For the test, disconnect the cable of the flow sensor from the input terminal no 26.
2. Start a manual rinsing procedure by pressing the "Water" key.
3. After 12 seconds the message "Füllstand, Check Levels, Niveau" appears on the control
display.
Notice: The message "Füllstand, Check Levels, Niveau" can be reset by simultaneously
pressing the "In/Out" and "Water" keys.
4. Reconnect the sensor cable to terminal no. 26.
EasyClean 350 e
EasyClean 350 e
52 500 194