5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location,
taking the reach and motion detection into
consideration. (Fig. 5.1)
• Reach for lateral movement (Fig. 5.2)
• Reach for movement towards the sensor
(Fig. 5.3)
Mounting procedure
– Undo retaining screw, detach enclosure from
wall mount. (Fig. 5.4)
– Switch OFF power supply (Fig. 5.5)
– Mark drill holes (Fig. 5.5)
– Drill holes and insert wall plugs (Fig. 5.6, 5.7)
– Fit sealing plug (Fig. 5.6, 5.7)
– Power supply lead, concealed (Fig. 5.6)
– Power supply lead, surface-mounted
(Fig. 5.7)
– Connect conductors (Fig. 5.8)
– Connect plug-in terminal (Fig. 5.9)
– Fit enclosure onto wall mount and screw in
retaining screw (Fig. 5.9)
– Fit glass shade and screw in retaining
screws (Fig. 5.10)
– Switch ON power supply (Fig. 5.10)
– Make settings
"6. Functions"
6. Functions
Once you have installed the wall mount, con-
nected the sensor-switched light to the power
supply and fitted the sensor lens, you can
put the sensor-switched light into operation.
Setting controls can be used for selecting three
settings. The light enters programming mode
as soon as the setting control is altered.
Function - control dials (Fig. 6.1)
Factory settings:
Time setting:
Twilight level:
Night-light function:
The settings may be altered as often as you
wish. The last setting made will remain stored
in the memory in the event of a power failure.
• To do this, detach cover (Fig. 6.1 J)
10 seconds
1,000 lux
OFF
- 13 -
Time setting (Fig. 6.1 K)
The light's ON time can be set to any period
from approx. 5 seconds to a maximum of
15 minutes.
– Setting control turned fully clockwise selects
the shortest time (approx. 5 seconds).
– Setting control turned fully anti-clockwise
selects longest time (approx. 15 minutes).
Note:
Select the shortest time setting to adjust the
detection zone and perform the function test.
Twilight setting (Fig. 6.1 L)
The chosen light threshold can be adjusted
continuously from approx. 2 lux to 1,000 lux.
– Setting control turned fully clockwise selects
daylight operation (approx. 1,000 lux).
– Setting control turned fully anti-clockwise
selects twilight mode (approx. 2 lux).
The setting control must be turned fully clock-
wise when setting the sensor-switched light for
the detection zone and performing the function
test in daylight.
Basic light function (Fig. 6.1 M)
The following functions can be controlled using
the dimmer control:
– Setting control dial turned clockwise switch-
es OFF the sensor-switched light.
Light is switched to maximum output when
movement is identified in the detection zone.
– Turning the setting control from mid-setting
to fully anti-clockwise adjusts light output to
any lighting level from approx. 10 % to 50 %
as basic light.
Note:
Basic light only with dimmable lamps
This means
light is only switched to maximum output
(100 %) from basic light level (e.g. 50 %) when
movement is identified in the detection zone.
– Brightness setting control fully anti-clock-
wise and twilight setting control set to fully
clockwise:
In this setting, the sensor-switched light works
in override mode (light permanently ON).
GB