GB
1. About this document
Please read carefully and keep in a safe
place.
– Under copyright. Reproduction either in
whole or in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in the
document.
...
2. General safety precautions
Disconnect the power supply before
!
performing any work on the unit.
• During installation, the electric power cable
being connected must not be live. Therefore,
switch off the power first and use a voltage
tester to make sure the wiring is off-circuit.
• Installing the sensor-switched light involves
work on the mains voltage supply. This work
must therefore be carried out professionally
in accordance with national wiring regula-
tions and electrical operating conditions.
(e.g.: DE - VDE 0100, AT - ÖVE-EN 1,
CH - SEV 1000)
3. L 115 S
Proper use
- Sensor-switched light with replaceable lamp
for mounting on indoor and outdoor walls
The integrated infrared sensor detects the
invisible heat radiated from moving objects
(people, animals, etc.). The heat detected in
this way is converted electronically into a signal
that switches the light ON automatically. Heat
radiation is not detected through obstacles,
such as walls or panes of glass - the sensor is
not triggered.
Important:
The most reliable way of detecting motion is to
install the sensor-switched light with the sensor
aimed across the direction in which a person
would walk and by ensuring that no obstacles
(such as trees and walls, for example) obstruct
the line of sensor vision.
Package contents (Fig. 3.1)
Product dimensions (Fig. 3.2)
Product components (Fig. 3.3)
A Retaining screw
B Mains power supply
C Wall mount
D Retaining screws
E Glass shade
F Twilight setting
G Switch-off delay
H Brightness control
I
Sensor lens
J Cover
4. Electrical installation
The mains supply lead is a 2 to 3-core cable:
L
= phase conductor (usually black or
brown)
N
= neutral conductor (usually blue)
PE = protective-earth conductor
(green / yellow)
Important:
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from
the power supply again. Connect the phase
conductor (L) and neutral conductor (N) to the
clamp-type terminal. The protective earth con-
ductor may be sealed off with insulation tape.
Note:
A mains switch for switching the unit ON and
OFF may of course be installed in the mains
supply lead. A mains switch is required for the
manual override function (see Manual override
function).
- 12 -