Safety recommendations for maintenance
Before doing any maintenance work, depressurise the water system and isolate the pump from all energy
sources.
When the jobs are done, before restarting the pump, check that no tools, rags or other materials have
been left close to moving parts or in hazardous zones.
Replace any excessively worn components with original parts and use the lubricants recommended by
the manufacturer.
Dispose of the worn-out components and lubricants in accordance with the relevant statutory
requirements.
Carry out the routine maintenance procedures specified by the manufacturer to keep the pump safe
and performing well.
Frequency
Every working day
Every 50 working hours
Every 500 working hours
or every year
Every 1000 working
hours
(1) This interval refers to the first oil change only
English
MAINTENANCE INSTRUCTIONS
Scheduled service table
Component
Filter
Pump
Connection of pump to
power source (pulley,
belt, coupling)
Pump
Pipes and connections
Pump
Pump
Pump gaskets
Valves
Procedure
Inspect filter cartridge
Oil level check
Inspection
Inspect mounting
Inspection
Oil change (1)
Oil change
Replacement
Replacement
35
7
Reference
See "Inspecting the filter"
See "Checking the oil
level"
-
See "Inspecting the
pump mounting"
See "Inspecting the
connections and pipes"
See "Changing the oil"
See "Changing the oil"
Contact an authorised
service centre
Contact an authorised
service centre
Use and Installation