Télécharger Imprimer la page

V2 FORTECO 2500-I-M Mode D'emploi page 33

Publicité

Les langues disponibles

Les langues disponibles

2 - TECHNICAL DATA
Gate maximum weight
Power supply
Maximum power
Idling current
Full load current
Gate maximum speed
Maximum thrust
Duty cicle
Pinion
Operation temperature
Weight
Protection
Maximum load on 24 VAC attachments
Protection fuses
WARNING: The following chart indicates the recommended maximum speed that can be programmed (via the
depending on door weight.
m
WARNING – DO NOT EXCEED THE INDICATED MAXIMUM SPEED
28,00
26,00
24,00
22,00
20,00
18,00
16,00
14,00
12,00
10,00
FORTECO 2500-I
2500 Kg
230VAC / 50Hz
650 W
0,5 A
3,7 A
0,035 ÷ 0,26 m/s
1660 N
50%
M4 - Z18
-20°C ÷ +55°C
19 Kg
IP44
10W
F1 = 8A
- 31 -
FORTECO 2500-I-M
2500 Kg
230VAC / 50Hz
650 W
0,5 A
3,7 A
0,035 ÷ 0,26 m/s
1660 N
50%
M4 - Z18
-20°C ÷ +55°C
21 Kg
IP44
10W
F1 = 8A
vEL
Parameter)
Peso del cancello [kg]
Gate weight [kg]

Publicité

loading

Ce manuel est également adapté pour:

Forteco 2500-i