Before you start...
Your safety and the safety of others are
very important.
We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential
hazards that can kill or hurt you and
others.
All safety messages will follow the safety alert
symbol and either the word "DANGER" or
"WARNING". These words mean:
Check location where washer will be
installed. Proper installation is your
responsibility. Make sure you have
everything necessary for correct installation.
Grounded electrical outlet is required.
See Electrical requirements.
Standpipe drain system: Needs 5 cm (2")
minimum diameter standpipe with minimum
carry-away capacity of 65 liters (14 Imperial
gallons) per minute. Top of standpipe must
be at least 99 cm (39") high and no higher
than 244 cm (96") from bottom of washer.
Do not tape hose into standpipe or close
the standpipe completely. An air path is
required to prevent siphoning.
Floor drain system: Requires a
siphon break, Part No. 285320,
available from authorized
distributors.
Support: Floor must be sturdy
enough to support washer weight
of 143 kilograms (315 lb).
SEE RECESSED AREA
INSTRUCTIONS ON
FRONT PANEL.
Tools needed for
installation:
Level
Utility
wrench
knife
Parts supplied for
installation:
Remove parts from packages.
Check that all parts were included.
1 small clamp
2 inlet hoses
Literature
4 flat water hose
package
washers
1 drain hose
2 front-leveling legs
1 hose clamp
with nuts
PANEL A
You can be killed or seriously injured if you
don't immediately follow instructions.
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will tell you what the potential
hazard is, tell you how to reduce the chance of
injury, and tell you what can happen if the
instructions are not followed.

Electrical requirements

Scissors
Pliers
Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or
electrical shock.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Important: Observe all governing codes
and ordinances.
A 120-volt, 60-Hz, AC-only, 15- or 20-
ampere fused electrical supply is required.
A time-delay fuse or circuit breaker is
recommended.
A separate circuit serving only this
appliance must be provided.
DANGER
WARNING
Important: Observe all
governing codes and
ordinances.
Level floor: Maximum slope
under entire washer –
2.5 cm (1").
WARNING
Hot and cold water faucets: Must
be within 1.2 meters (4') of the back
of the washer and provide water
pressure 34 to 690 kPa (5-100 psi).
Untape and open washer lid.
Remove all material from washer.
Laundry tub drain system:
Needs a 75 liter (16.5 Imperial
gallon) laundry tub. Top of tub
must be at least 87 cm (34") high
and no higher than 244 cm (96")
from bottom of washer.
If a longer drain hose is needed, a
drain hose, Part No. 388423 and
hose extension kit, Part No. 285442,
are available from authorized parts
distributors at additional cost. If drain
hose must be shortened, use kit
(Part No. 285442).
Do Not store or operate washer
below 0°C (32°F) (some water
may remain in washer).
See Use & Care Guide for
"Winterizing" information.
Water heater: Set to deliver 60°C
(140°F) water to the washer.
Recommended
ground method
The washer, when installed, must be
electrically grounded in accordance with
local codes, or in the absence of local
codes, in the U.S.A., with National Electrical
Code ANSI/NFPA 70*, or in Canada, with
Canadian Electrical Code, CSA C22.1**.
GROUNDING INSTRUCTIONS: This
appliance must be grounded. In the event of
malfunction or breakdown, grounding will
reduce the risk of electric shock by
providing a path of least resistance for
electric current.
The power supply cord plug must be
plugged into an appropriate outlet that is
properly installed and grounded in
accordance with all local codes and
ordinances.
WARNING - Improper connection of the
equipment-grounding conductor can result
in a risk of electric shock. Check with a
qualified electrician or serviceman if you are
in doubt as to whether the appliance is
properly grounded. Do not modify the plug
provided with the appliance - if it will not fit
the outlet, have a proper outlet installed by a
qualified electrician.
Copies of the standards listed may be obtained
from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
3-prong
ground-type
outlet
3-prong
ground
plug
Power
Ground
supply
prong
cord