CS.SE.IST-1 / Rev 1.0
Technical Specifications
Nominal heat input
Reduced thermal capacity
Nominal thermal output
Reduced thermal power
Efficiency at thermal nominal power
Efficiency at reduced thermal power
CO at 13% oxygen at nominal thermal power
CO at 13% oxygen at reduced thermal power
Maximum power uptake
Power uptake when running
Nominal voltage
Nominal frequency
Flue outlet diameter
Air intake pipe diameter
Minimum chimney draught at nominal thermal power
Minimum chimney draught at reduced thermal power
Combustion gas mass at nominal thermal power
Combustion gas mass at reduced thermal power
Ventilated pellet tank capacity
Average exhaust flue gas temperature at nominal thermal power
Average exhaust flue gas temperature at reduced thermal power
Minimum safety distance from flammable materials (side/rear/front)
* Power consumption only during the ignition cycle.
The appliance's heat output may vary depending on the type of pellets used.
Dimensions and connections data sheet
All the data sheets of dimensions and connections are visible by scanning the following QR Code from your smartphone:
1
https://docs.klover.it/it/guide/help/cs-se60-tds-1
kW
kcal/h
kW
kcal/h
kW
kcal/h
kW
kcal/h
Watt
Watt
mm
mm
mm
2
https://docs.klover.it/it/guide/help/cs-se80-tds-1
4
1
DEA ECO 6
6,3
5.420
4,1
3.530
5,6
4.820
3,8
3.270
%
89,2
%
91,9
%
0,016
%
0,034
300*
60
V
230
Hz
50
80
33
Pa
10
Pa
10
g/s
5,0
g/s
4,0
kg
15
°C
140,1
°C
95,5
200 / 200 / 800
200 / 200 / 800
https://docs.klover.it/it/guide/help/cs-se120-tds-1
ENGLISH
2
3
DEA ECO 8
DEA ECO 12
7,5
11,3
6.450
9.720
4,2
5,3
3.610
4.560
6,8
9,6
5.850
8.260
3,8
4,5
3.270
3.870
90,0
85,3
91,2
85,2
0,015
0,008
0,034
0,026
300*
300*
60
60
230
230
50
50
80
80
33
33
10
11,5
10
10,2
5,5
7,7
4,0
5,4
18
27
139,5
213,3
95,5
153,9
200 / 200 / 800
3