5.1 Change temperature setting
Wake-up the thermostat by pressing any key.
Press
or
, to change the temperature set
point (digits starts to blink).
By pressing validation key
set point value is validated.
5.1.1 Boost/Timer mode
In mode boost, set point temperature is
applied during a selected time.
After this time, thermostat will return to former
mode.
You can first adjust, the desired setting tem-
perature with
, to validate, default value 24°C.
In a second time, you can adjust the du- ration
in hours "H" if below 24H, then in day "d".
With automatic H&C switching configuration,
boost/timer mode can't be selected.
If configuration system is changed by H&C
signal, boost/timer mode will be stopped.
Thermostat will return to the previous select-
ed mode.
Default value: "no" (0 minute)
Value range: 1h to 23 hours (step of 1 hour)
and 1 day to 44 days (step 1 day).
5.1.2 Comfort mode
In this mode, comfort temperature set point
will be followed all the time.
This mode can't be selected if thermostat is a
"slave" product and H&C signal sends reduced
information.
5.1.3 Reduced / ECO mode
In this mode, reduced temperature set point
will be followed all the time.
8
|
|
Nederlands
Français
, temperature
or
, press validation key
|
Deutsch
This set point corresponds to comfort set point
reduced by an offset (see paragraph 7.2 "User
parameter description").
Reduced/ECO mode is available if if thermostat
is in master configuration;
If H&C signal is in ECO mode and the thermo-
stat is configured in slave, the thermostat is set
automaticaly in ECO configuration
Note: In cooling mode, reduced mode acts
like the OFF mode (system is stopped, NC
actuators are closed).
Thermostat is in master configuration when
logo mode is
Thermostat is in slave configuration when logo
is without the frame
Important notes:
- With "Floor Limit" regulation, Reduced/ ECO
mode couldn't work properly if "Low limit"
value is too high;
- If system configuration is automatic H&C
switching and thermostat is system master,
user can't set derogation.
- If configuration system is changed by H&C
signal, setpoint derogation will be stopped.
5.1.4 Anti-freeze mode
Use this mode if you want to protect your
installation against freezing. (default value 7°C).
.
.