Cycle time setting
This menu is displayed only if parameter "Typ" (#26) is equal to
"bp".
Use minus
The setting is validated with validation key
Default value: 10 minutes
Proportional Band
This menu is displayed only if parameter "Typ" (#26) is equal to
"bp".
Use minus
The setting is validated with validation key
Default value: 2°C
First parameter of H&C signal: width of death band
This menu is displayed only if parameter "Mod" (#07) is equal to
"Aut" or "Aut" is selected in "Reversible" mode menu.
This parameter corresponds to width of death band.
Use minus
The setting is validated with validation key
Default value: 1°C
Second parameter of H&C signal: time threshold
This menu is displayed only if parameter "Mod" (#07) is equal to
"Aut" or "Aut" is selected in "Reversible" mode menu.
This parameter corresponds to a time threshold.
Use minus
ed with validation key
Default value: 1H
Minimum value of setting range of the set point
temperature
Default value: 5.0°C
Maximum value of setting range of the set point tem-
perature
Default value: 30.0°C
and plus
keys to set cycle time value.
Other values: [10 15 30 45 60]
and plus
keys to set proportional band value.
Value range: 2°C to 5°C
and plus
keys to set value.
Value range: 0°C to 5°C by step of 0.5°C
and plus
keys to set value. The setting is validat-
.
Other values: no, 30' , 2H, 3H, 4H and 5H
Value range: 5.0°C to 15.0°C
Value range: 20.0°C to 37.0°C
.
.
.