5. TECHNICAL SPECIFICATIONS.
TECHNICAL DATA.
FUNCTION:
VOLTAGE/FREQUENCY.
MAXIMUM ABSORBED POWER.
MAXIMUM EFFICIENT POWER.
OPEN CIRCUIT VOLTAGE / WELDING
VOLTAGE AT 120A.
POWER FACTOR / EFFICIENCY.
WELDING REGULATION.
DUTY CYCLE AT 120A.
Ø MAXIMUM ELECTRODE.
CLASSE DE ISOLAMENTO
DEGREE OF PROTECTION
DIMENSIONS
WEIGHT
Orientative table of welding parameters and performance (X%) depending on the diameter of
a rutile E6013 electrode and the material to be welded.
Thickness of pieces to be welded
Electrode E6013
Welding current
MINI125
(*)Operating factor for a 10-minute cycle (UNE EN 60974). For example, an operating factor of 40%
corresponds to a 4-minutes charging period, followed by a 6-minutes idling period.
6. COMMISSIONING.
This machine is equipped with an input voltage compensation device. When the supply voltage changes
within ± 15% of the nominal value, (230V.), It will continue to operate normally. When using a long cable,
a thicker cable is suggested to avoid voltage drop.
If you use welding cables that are too long, it can affect the performance of the equipment. We suggest
that you use the cables provided with the machine.
1. Make sure the air inlet to the fan is not blocked or covered, so that the cooling system works
efficiently.
2. Use an induction cable no less than 6mm² to connect the case to ground. This is done through a
ground connection at the rear of the machine.
3. Make sure the power cord is connected to a grounded outlet (socket). The earth conductor of
the device must have a minimum section of 6 mm².
4. Connect the work clamp lead to the "+" polarity on the front panel, fix it clockwise, and connect
the work clamp to the workpiece.
5. Observe the connection polarity correctly, this machine has two connection possibilities: Direct
and Reverse.
6. Direct Connection: the electrode holder is connected in the "-" polarity, while the workpiece is
connected with the "+" polarity, by means of the earth clamp.
(A).
Up to mm.
Ø (mm.)
I₂ (A.)
X% (*)
28
MINI125
MMA
1~ 230V. – 50/60Hz.
21A
13A
60V
0,73 / 84.09%.
20-120A
40%
3,25mm.
F
IP21
220x100x140mm.
2,2 Kg.
2
3
1,6
2,0
2,5
40-55
55-80
80-115
100%
100%
100%
5
8
3,25
115-140
40%

Publicité