Operation
appliance remains in trickle-charge mode, even if
the user switches over to another mode. This pro-
tects the battery from being damaged.
mode 1 „6 V" (7.3 V / 0.8 A)
Q
This mode is suitable for charging 6 V lead-acid
batteries with a capacity less than 14 Ah.
P ress the selection button MODE
mode 1. After doing so, the corresponding LED
display „6 V"
lights up. If you do not activate
2
an-other process afterwards, the electronic sys-
tem will automatically start the charging process
together with the LED display
current of 0.8 A ± 10 %. If the procedure runs
without any problems, the LED display
remains on during the entire charging process, un-
til the battery is fully charged at 7.3 V / ± 0.25 V.
When the battery is fully charged, LED display
lights up and LED display
7
out. The device now switches automatically into
maintenance charging mode.
mode 2
„12 V" (14.4 V / 0.8 A)
Q
This mode is suitable for charging 12 V lead-acid
batteries with a capacity less than 14 Ah.
P ress the selection button MODE
mode 2. After completion of this process, the
appropriate LED indicator
Then if you do not take any further action, the
electronic control and the LED indicator
automatically switches on and starts the charg-
ing process. If the procedure runs without any
problems, the LED display
during the entire charging process, until the
battery is fully charged. When the battery is
fully charged, LED display
LED display
8
switches automatically into maintenance charg-
ing mode.
46 GB
, to select
9
at with a
8
goes
8
, to activate
9
lights up.
3
remains on
8
lights up and
7
goes out. The device now
mode 3
Q
This mode is mainly suitable for charging 12 V
lead-acid batteries with a capacity greater than
14 Ah under normal conditions.
P ress the selection button MODE
mode 3. Then if you do not take any further ac-
tion, the electronic control and the LED indicator
switches on and starts the charging pro-
4
cess. If the process runs without any problems,
the LED indicator
whole charging process until the battery is
charged. When the battery is fully charged, the
LED indicator
go out. The device now switches auto-
8
matically into maintenance charging mode.
8
mode 4
Q
This mode is used for charging 12 V lead-acid bat-
teries with a capacity greater than 14 Ah under
cold conditions or for charging some AGM (Absor-
bent Glass Mat) batteries with a capacity greater
than 14 Ah.
P ress the MODE selection button
mode 4. As you select the desired mode, the
appropriate LED indicator
mediately. If you take no further action, the elec-
tronic control switches on after a preset delay
to begin the charging process. In this mode the
charging current is the same as in "mode 3". If
the process runs without any problems, the LED
indicator
switches on and remains in this state until the
8
battery is charged. As soon as this point is
reached, the battery charger switches to main-
tenance charging mode. Now the LED indicator
goes out and the LED indicator
8
lights up to indicate the present status.
„12 V" (14.4 V / 3.8 A)
, to activate
9
remains on during the
8
and the die LED indicator
7
„12 V" (14.7 V / 3.8 A)
to select
9
lights up im-
5
lights up, the electronic control
8
7