Control options
UNIT STATUS
The unit status can be selected from the Aidoo device, enabling on/off control of both the room
thermostat and the circuits, as well as domestic hot water (DHW).
OPERATION MODES
The modes that can be selected from the device are: Cooling mode, Heating mode and Auto
mode.
If the unit is operating in Auto mode, its operation will depend on the outdoor temperature and
the thermostat room temperature.
DHW CONTROL
The manufacturer's units allow you to manage domestic hot water (DHW) production status
control. The "Powerful" function can be activated in DHW production status control, which
forces the DHW to reach a temperature that has been preset in the configuration of the unit. If
DHW is turned off, it will not be possible to activate this parameter.
WORKING SETTINGS
The manufacturer's units can operate in room temperature mode (TH), in water supply
temperature mode (TAI), and in external room thermostat mode (external TH). The Aidoo
device must be configured to operate in TH mode or in TAI mode in order to function correctly.
The Aidoo device will be able to regulate the temperature in one or two circuits in TAI mode,
while it can only regulate one circuit in TH mode.
SET-POINT TEMPERATURE
The unit temperature will depend on the working settings:
•
In TH mode, the thermostat room temperature will be selected, and in TAI mode, the water
supply temperature at which the unit is to operate will be selected.
•
The DHW temperature can be selected within the ranges set by the unit's own main
thermostat.
The temperature limits can be selected from the unit's main thermostat, both for TH mode
and for TAI mode. The maximum DHW temperature value can be selected, but the minimum
value cannot be configured.
EN
11