Cleaning, Care & Maintenance
Always turn off and disconnect the appliance from the power supply before
cleaning.
Always allow the appliance and oil to cool before cleaning.
Check the temperature with a suitable probe thermometer; 40ºC is the MAXIMUM temperature at
which oil should be removed.
For best performance, BUFFALO recommend that the appliance is cleaned after each day of operation.
Pull the air filter out of its slot on the bottom of the appliance. Clean with a vacuum cleaner.
Note: Failure to clean the appliance regularly may result in premature activation
of the thermal cut-out switch.
Empty and clean the oil tank
When the oil has cooled sufficiently, lift the tap lever and rotate anti-clockwise to the ON position. Let
the drained oil flow into a container.
Tap: OFF position
If the oil is to be reused then filtering it before refilling will extend the oil's cooking life.
Use a suitable detergent to clean the oil tank.
Let it dry well, ensuring no moisture enters the inside of the appliance.
Cleaning all removable parts
Use warm, soapy water and a soft brush to clean the lid, basket and batter plate.
Dry thoroughly.
A BUFFALO dealer or qualified technician should carry out repairs if required.
Troubleshooting
Error indications
HEATING
IGBT on the PCB is
indicator light
overheated. Buzzer
flashes once
alarms.
continuously
6
CP793_CT012_ML_A5_v3_20180927.indb 6
Description
Probable Cause
Check ventilation
slots for dirt and
grease. Make sure
there is enough
space around the
appliance.
Tap: ON position
Solution
1. Switch the unit off and let it cool.
2. Check the filter and clean if
necessary.
3. Re-start the unit.
Note: If it occurs frequently, call
BUFFALO agent or qualified technician
2018/9/27 09:54