Télécharger Imprimer la page

Nordcap TMV-M22 Manuel D'instruction page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
5. OPERATION
5.1 THERMOREGULATOR AND TEMPERATURE SETTING
Valid for all models except:
KEYS FUNCTION ON THE CONTROL PANEL
Start/Stop appliance
Turn lights on/off
To view / edit the setpoint
For manual defrosting
To decrease temperature
To increase temperature
To turn on the heating element on the frame/ rails
To switch on the inside fan
SETTING THE TEMPERATURE
To set the desired temperature press
Press the keys
The temperature shown on the display is taken by the probe located inside the cabinet at the bottom of the central aluminum
panels.
MANUAL DEFROST
The product is equipped with an automatic defrost system, therefore no manual intervention is required. If you wish to perform an
additional manual defrost, press and hold for at least three seconds the key
stop the appliance will run again the normal operation with the previously programmed temperatures.
PARETE - MOD
Static
1
2
+16°C
+20°C
+12°C
+18°C
+8°C
+16°C
+4°C
+14°C
+4 / +16 °C
+14 / +20 °C
SET 4 °C
SET 14 °C
OFF
OFF
TA 35°C
TA 30°C
Reported temperatures are approximate and may vary by ( + - ) 2 °C depending on the model chosen (Wine Showcase,
Gastronomy, Delicatessen)
The temperature controller of wine units can be set to different temperatures with or without ventilation directly by
the user, allowing to choose the right conservation or service temperature for all types of wine.
Please remember that the bottom part of the showcase is always few degrees lower than the upper part, fact that
has to be considered when choosing the position of the different wines.
. The symbol
to set the temperature. Press again the key
POSSIBLE SETTINGS
Ventilated
3
+8°C
+16°C
+4°C
+14°C
+4 / +8 °C
+4 / +16 °C
SET 4 °C
SET 14 °C
ON
TA 30°C
TA 35°C
SUGGESTED SERVING TEMPERATURES OF WINE
MEANING OF THE WARNING SYMBOLS ON DISPLAY
Compressor on
Light on
Defrosting on
Frame heating on
Inside fans on
Temperature alarm
(ON) Actual temperature
(FLASHING) Set point in progress
will start flashing.
to confirm your choice.
in order to stop the cooling for fifteen minutes. After this
u. r. 50%
Static
4
1
+16°C
+12°C
+8°C
+4°C
+4 / +16 °C
SET 4 °C
ON
OFF
TA 25°C
13
TECA
Ventilated
2
3
+20°C
+12°C
+18°C
+16°C
+14°C
+6°C
+14 / +20 °C
+6 / +12 °C
SET 14 °C
SET 6 °C
OFF
TA 30°C
TA 25°C
4
+16°C
+14°C
+14 / +16 °C
SET 14 °C
ON
ON
TA 30°C

Publicité

loading

Ce manuel est également adapté pour:

446122001