GB
We decline any liability for damage caused
by inappropriate repair attempts. Any
damage caused by inappropriate repair
attempts will avoid all warranty claims.
Regular maintenance and thorough care will reduce
the danger of possible malfunction and contribute to
an extension of the lifetime of your unit.
If the pump is to be put out of operation for some
extended period of time, it should be emptied
completely in by opening the water drain screw (7).
Subsequently, please flush the pump with clean
water. Then allow the pump body to dry completely
in order to prevent corrosion damage.
Cleaning the coarse filter insert.
When closing the cap, DO NOT OVERTIGHTEN
TO CRUSH THE PLUG.
Water left in the pump may freeze in case of frost and
Malfunction
The pump is not
discharging any liquid,
the motor is not
running.
The motor is running,
but the pump is not
discharging any liquid.
Possible cause
No current.
Thermal motor protection feature has
triggered.
The capacitor is defective.
The motor shaft is jamming.
The pump housing is not filled with
liquid.
Air penetrates into the intake line.
Suction height and/or discharge height
too great.
thus cause considerable damage. Please store the
pump in a dry, frost- protected place.
In the case of malfunction, you should first of all
check whether it was caused by an operating error
or some other reason which cannot be attributed to
a defect of the device - for instance a power failure.
The list below shows some possible malfunctions
of the device, possible causes and tips on their
elimination. All the measures referred to may only
be carried out with the pump being separated from
the electrical mains. If you yourself feel unable to
eliminate any of these malfunctions, please contact
the customer service department or your point of
sales. Any repair beyond the scope specified below
must only be performed by qualified staff. Please
bear in mind that all warranty claims will become
void in the case of damage caused by inappropriate
repair attempts, and that we decline any liability for
any ensuing damage.
Elimination
Please use a device complying with GS
(German technical supervisory authority)
to check for the presence of voltage
(safety information to be observed!).
Please verify.
Separate the pump from the electrical
mains, allow the system to cool down,
eliminate cause.
Please contact the customer service
department.
Check the cause, eliminate the reason for
the jamming of the pump.
Fill the pump housing with liquid (please
refer to "Putting into operation" section).
Check to make sure that :
a.) the connection points of the intake
line are tight.
b.) the inlet opening of the intake line
including the check valve (non-return
valve) are immersed into the liquids
being discharged.
c.) the check valve (non-return valve)
with the filter is tight and not jammed.
d.) no siphons (i.e. permanently liquid-
filled loops), kinks, counter-slopes or
narrow spots are present along the
intake lines.
Change the arrangement of the
installation so that the suction height
and/or discharge height will not exceed
the max. value.