3. Using the rubber tube from the pressure check
measuring device, slide the rubber tube down over the
gas pressure test port. The rubber tube should seal
around the pressure test port on the range. (Fig.8)
4. Turn on the LP gas to the appliance.
5. The pressure gauge tester should measure between 11"-
13.8" WC.
Fig. 8
6. Turn off the LP gas to the appliance.
7.
Remove the rubber tube of the pressure check
measuring device.
8. Replace the screw with the gasket from step 2. Before
replacing the screw, inspect the rubber gasket seal for
any signs of damage. Replace seal if damaged.
9. Tighten the screw to 1.3 Nm to 1.7 Nm.
NOTE: Ensure the product is gas leak checked after the pressure
check test is completed by also testing the pressure check port
screw. If any leaks are detected around the pressure check port
screw and gasket, a new one can be purchased. Call Furrion
support for a replacement.
Leak Check
WARNING
●
Gas leaks may occur in your system and result in a
dangerous situation. Always perform a leak test for possible
leaks according to the manufacturer's instructions after
installation and before any operation.
●
Gas leaks may not be detected by smell alone. Gas
suppliers recommend you purchase and install a UL
approved gas detector.
WARNING
FIRE OR EXPLOSION
●
Extinguish all open flames.
●
Never leak test when smoking. Never use a flame.
●
Do not use the appliance until the connection has been
leak-tested and does not leak.
1.
Ensure all control knobs are in the OFF position.
2. Apply a gas leak detection liquid (soapy water) to the
connections. If there are bubbles presented, there is a
gas leak.
3. If a gas leak is detected, tighten the loose joint, or replace
the faulty part with a replacement part recommended by
Furrion
authorized retailer.
CCD-0006069 Rev: 12-04-23
Electrical Connection
PRODUCT DAMAGE HAZARD
●
Connect to 12V DC service only.
●
Connect only to protected circuit fused for not more than 15
Amps.
●
DO NOT hi-pot range unless electronic ignition system has
been disconnected.
Connection wires are located at the right back of the unit. Connect
to the red wire to the positive DC supply wire from the distribution
box and connect to the black wire the negative DC supply wire.
(Fig.9)
Fig. 9
NOTE: Ensure to connect the wires with the correct polarity. Red
is "+" and Black is
"-". A grounding hole is provided if needed.
+
-
22#AWG
VDD
GND
Pulse igniter
Bi-Fold Glass Cover Replacement
1.
Align the bi-fold glass cover assembly with the slots on
the cooktop and place it into the cooktop.(Fig.10)
Fig. 10
- 6 -
CAUTION
22#AWG
Knob light switch
Red
Blue
Lamp board(Front)
Lamp board(Back)
Red
Blue
Furrion