TECHNICAL PARAMETERS
Outdoor unit:
Outdoor side heat exchanger of air conditioner/heat pump:air
Indoor side heat exchanger of air conditioner/heat pump:water
Type: compressor driven vapour compression
Driver of compressor:electric motor
Indication if the heater is equipped with a supplementary heater:yes
Parameters shall be declared for the average heating season
Item
Parameters shall be declared for:
Indoor heat exchanger:
Rated heating capacity
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Tj = – 7
Tj = 2
Tj = 7
Tj = 12
Tj = bivalent temperature
Tj = operating limit
Bivalent temperature
heating/Average
heating/Warmer
heating/Colder
Degradation co-efficient
Off mode
Thermostat-off mode(heating)
Supplementary capacity
Capacity control
Reference annual heating
demand
Annual energy consumption
Contact details
Technical parameters
AHW-080HCDS1
Symbol
Value
Unit
Heating
5.90
P
kW
rated,h
Pdh
5.2
kW
Pdh
3.2
kW
Pdh
2.1
kW
Pdh
2.1
kW
Pdh
5.2
kW
Pdh
5.7
kW
Tbiv
-7
Tbiv
Tbiv
Cd
0.9
Power consumption in modes other than 'active mode'
P
0.010
kW
OFF
P
0.011
kW
TO
Supplementary heater
P
0.179
kW
SUP
Other items
Variable
Q
12081
kWh
H
Q
3536
kWh
HE
Qingdao Hisense Hitachi Air-conditioning Systems Co., Ltd
No. 218, Qianwangang Road, Economic and Technological Development Zone, Qingdao, China
Indoor unit:
Item
Medium temperature application
Variable outlet
Seasonal space heating
energy efficiency
Declared coefficient of performance/Average season, at
indoor temperature 20 °C and outdoor temperature Tj
Tj = – 7
Tj = 2
Tj = 7
Tj = 12
Tj = bivalent temperature
Tj = operating limit
Operating limit temperature
heating/Average
heating/Warmer
heating/Colder
Standby mode
Crankcase heater mode
Type of energy input
air flow rate, outdoor
Sound power level ,
indoor/outdoor measured
Global warming potential
28
AHM-080HCDSAA
Symbol
Value
unit
η
134
%
s,h
COPd
1.85
COPd
3.40
COPd
4.50
COPd
7.71
COPd
1.85
COPd
1.54
Tol
-10
Tol
Tol
P
0.010
kW
SB
P
0.001
kW
CK
Electric
3
2700
m
/h
LWA
42/64
dB(A)
kgCO
eq.
GWP
675
2